Previous image
Fluke 101 Basic Digital Multimeter Pocket Portable Meter Equipment Industrial
Next image
缩放图片

Fluke 101 Basic Digital Multimeter Pocket Portable Meter Equipment Industrial


尚未评级
有现货 ({{多个}}商品有售)

Basic dc accuracy 0.5%

CAT III 600 V safety rated

Diode and continuity test with buzzer, Rugged, durable design.

Small lightweight design for one-handed use

Automatic shutdown, Battery is easy to replace

  • $114.00
数量:  
  • 重量
    0.7 千克
  • 库存单位
    10000000188
Electrical Specifications
V AC (40-500Hz)Range600.0 mV
6.000 V
60.00 V
600.0 V
Resolution0.1 mV
0.001 V
0.01 V
0.1 V
Accuracy3.0%±3 digit
1.0%±3 digit
V DCRange6.000 V
60.00 V
600.0 V
Resolution0.001 V
0.01 V
0.1 V
Accuracy0.5%±3 digit
Resistance OhmsRange400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
Resolution0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy0.5 %±3 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
0.5 %±2 digit
1.5%±3 digit
CapacitanceRange50.00 nF
500.0 nF
5.000 μF
50.00 μF
100.0 μF
Resolution0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
Frequency
(10 Hz – 100 kHz)
Range50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
Resolution0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
Duty CycleRange0.1 % to 99.9 %
Resolution0.1 %
General Specifications
CAT RatingCAT III 600 V
V AC Range600.0 V
V DC Range600.0 V
Ohms Range40.00 MΩ
Auto ShutoffY
ContinuityY
Capacitor100.0 μF
Frequency100.0 kHz
HoldNo
Duty CycleYes
Size130 mm x 65 mm x 27mm 
Weight160 g
BatteryTwo AAA
Warranty1 year
Environmental Specifications
Operating Temperature0 °C to +40 °C
Storage Temperature-30 °C to +60 °C
Operating HumidityNon condensing (<10 °C)
<=90% RH (at 10 °C to 30 °C)
<=75% RH (at 30 °C to 40 °C)
(Without Condensation)
Operating Humidity, 40 MΩ80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C
Operating Altitude2,000 meters
Storage Altitude12,000 meters
IP RatingIP 40 per IEC 60529
Vibration RequirementsMIL-PRF-28800F, Class 2
Drop Test Requirements-10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment
Shipping container drop per Fluke SOP 39.
EMI, RFI, EMCMust meet all applicable requirements in
IEC/EN 61326-1
Absorption/CorrosionPer Fluke SOP 39.1
Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC

Package Include:

1 x Fluke 101  Multimeter

1 x TL175 TwistGuard™ Test Leads (as same picture)

顾客评论
请登录然后增加评论
There are no comments yet. Be the first to leave a comment